The box must have a minimum depth of 21 8. The mmf 300 can be used to replace m300 modules in existing systems.
Hybrid Polymer Metal Oxide Thin Films For High Performance
Mmf 300 wiring diagram. Mmf 300 applications use to monitor a zone of four wire smoke detectors manual fire alarm pull stations waterflow devices or other normally open dry contact alarm activation devices. Mounting hardware and installation instruc tions are provided with each module. All wiring must conform to applicable local codes ordinances and regulations. They may also be mounted to the smb500 sur face mount box. It provides either a 2 wire or 4 wire fault tolerant initiating device circuit idc for normally open. Mmf 300 wiring diagrams connect the slc wiring to the module terminals 1 and 2.
Direct dial entry of address. The mmf 300 mounts directly to 4 square electrical boxes see figure 2. Sems screws with clamping plates for ease of wiring. All wiring must conform to applicable local codes ordinances and regulations. Direct dial entry of address. Each module takes one address on the slc.
This module is intended for power limited wirin g only. Refer to setting an slc address for a single point module on page 34. Wiring a nfpa style d idc with an mmf 300. Refer to setting an slc address for a single point module on page 34. The mmf 302 mounts directly to 4 square electrical boxes see figure 2a. Use the rotary switches on the module to set it to the required slc address.
The box must have a minimum depth of 21 8. Surface mounted electrical boxes smb500 are available. Intelligent control panel s l c wiring manual document 51309 2142008 rev. This module is intended for power limited wirin g only. Mmf 300 wiring diagrams 533 mmf 300 wiring for emergency alarm system applications connect the slc wiring to the module terminals 1 and 2. The mmf 300 monitor module is intended for use in addressable two wire systems where the individual address of each module is se lected using the built in rotary switches.
All wiring must conform to applicable local codes ordinances and regulations. Led flashes during normal operation and latches on steady to indicate alarm. The mmf 300a monitor module is intended for use in intelli. K pn 51309k ecn 08 118. The mmf 300a monitor module is intended for use in intelli. Sems screws with clamping plates for ease of wiring.
Led flashes during normal operation and latches on steady to indicate alarm. Use the rotary switches on the module to set it to the required slc address. Mmf 300 mmf 302 and mdf 300 modules mount directly to a standard 4 1016 cm square 2125 5398 cm deep electrical box. May also be used to monitor normally open supervisory devices with special. Each module takes one address on the slc. 01 159 on ms 9600 series panels 01 99 on other compatible systems.
01 159 on ms 9600 series panels 01 99 on other compatible systems. Surface mounted electrical boxes smb500 are available.