The 1006 is supplied as a 12 volt dc unit. Latchbolt monitor diagram 4.
Model 660 Electric Door Lock Installation Instructions Please
Hes 51wk wiring diagram. Class agenda 3 what is the heart of the eac system. Wiring diagram lbm if the answer is 12 16 volt continue to step 6. Its strength is derived from a unique keeper pin locking design enabling the 5000 to exceed the ratings of the. Hes 9500 electric strike. The surface mounted windstorm rated solution. At the request of hes this model was tested and verified by ul for the following voluntary not required ratings.
Be advised that with a 16 volt source the model 5000 is capable of a 10. The fire rated concealed solution for mortise latchbolt locks. The in frame adjustable feature allows the installer to easily adjust the electric strike opening to accommodate the horizontal position of the latchbolt after installation. Hesfolger adamssecuritronadams ritealarm controls. The 7000 series offers two solutions to address preloaded doors. Finish installing prepare frame lbm wiring white orange normally open.
Before connecting any device at the installation site verify input voltage and current using a multimeter. A 12 volt dc fig. Hes 9400 electric strike. Hes 7000 electric strike. The slim line surface mounted solution for rim exit devices. All components are completely encased within its 34 thick stainless.
Jamb view the 4500 is the first strike designed for installation in 2 ul 10c fire rated frames with 12 drywall penetration 12383 4 78 7938 3 58 318 1 14 244 1 12 lbm wiring white orange normally open green normally closed common diagram 3. Wiring diagrams and electrical specifications electrical ratings continuous duty for solenoid 24 vdc 12 vdc resistance in ohms 96 267 watts seated 6 45 amps seated 25 45 solenoids are rated at 5 indicated value caution. If the answer its 24 volt please follow the instructions below. The 5000 series is a compact high performance electric strike designed for low profile openings where there is limited space behind the jamb. Hes 9600 electric strike. Power supplies boards and the circuit wiring circuit lets make it work.
Laying out the circuit diagram team system project open discussion and questions access control the basics exiting switches existing. For 24 volts dc see figure b. The 9600 series is a windstorm rated surface mounted electric strike designed to accommodate rim exit devices with a 34 throw latch. Faceplates accessories documents certifications listings. B 24 volt dc note. Faceplates accessories documents certifications listings.
Monitor lbsm see diagram 3 4 to complete wiring. What does the strike wiring configuration need to be. Hes 5000 electric strike. Hes 8500 electric strike. Install the electric strike unit in jamb cutout using the screws provided with the faceplate option kit. Installation diagrams 3 diagram 7.
Connect wires from the power source to the strike. If horizontal adjustment is needed see diagram 6. Faceplates accessories documents certifications listings. Includes hes 8300 strike body 801 faceplate and 801a faceplate. For 16 volt acdc operations maintain the solenoid wiring configured for 12 16 v. 3000 lbs static strength rating 2000000 cycles of operation wiring diagram for 1224 volts fig.