Electrical wiring diagram of the house. Apparently the sparkies have done some work in the meter box and now every time they switch a light on the switch on the ripple control receiver flicks to the off position.
Reference Designs Digikey Electronics
Ripple control receiver wiring diagram. Document and amendment history issue no. The timer will close its switch and provide power to the control line on the contactor which in turn allows the inverter to be connected back into the network. It is a remote controlled switch that the council can control. Date approved by summary of changes 1 june 2009 m practice procedures dor this document supersedes the previous. It contains a ripple receiver which receives signals from the electricity supplier that switches on or off power. As a standard the enermet ro ripple control receiver operates on the basis of an internal clock which is used for the time programs the learning function and the telegram memory.
We also recognise the investment made by customers that install storage water heaters to accommodate peak control or night only heating. Equipment and wiring must have adequate load and fault ratings. Guys my youngest daughter lives in a rental and the landlord is currently they are building a granny flat in the backyard. I have had various questions regarding what does the zellweger ripple control at the other end. Therefore the enermet ro receiver with optional real time clock is an ideal solution for time switch applications without ripple control systems in place or for future introduction of ripple control systems. They turn your geyser off when the deman for electricity is very large in order to reduce the load.
Times can be programmed. There are no timers on the switchboard as i have seen in hobart for example where they do not use ripple control but have daynight rates. At least on the orion christchurch network anyway. The clock goes by the mains frequency and can be synchronized by means of ripple control signals. A couple of thousand of these ripple relays. 24 orions commitment to ripple control orion recognises the investment made by electricity retailers and their metering providers when installing and maintaining ripple relay receivers.
Ripple control commands failsafe function or power on function can activate or de activate these time programs. These diagrams apply only to northpower owned metering equipment includes ripple receiver contactor. If a power down occurs the current time is stored. Ripple control does switch your cylinder off and on each night it is not just for load shedding. Here we have the ripple relay on a domestic meter board. If a load greater than 2a is controlled eg spa pool the customer is required to fit an auxilary contactor.
A ripple relay in laymans terms. Northpower will supply a controlled supply to a maximum rating 2a.