To a compatible notifier system control panel only list available from notifier. Notifier fcm 1 wiring diagram.
Notifier Frm 1 Addressable Control Relay
Notifier fdm 1 wiring diagram. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 4. 412 h x 4 w x 114 d mounts to a 4 square by 218 deep box accessories. Trical boxes smb500 are available from notifier. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. All wiring must conform to applicable local codes or dinances and regulations.
Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. Summary of contents for notifier fdm 1 page 1 compatibility requirements a78 2318 13 to ensure proper operation this module shall be connected to a figure 2a. Install module wiring in accordance with the job drawings and appropriate wiring diagrams. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools. Connecting a releasing device to a fcm 1 module connecting an. Monitor modules model numbers include the fmm 1 fmm 101 fzm 1 and fdm 1.
Notifiers offers a variety of intelligent monitor modules for diverse applications. Notifier nfse manual online. Notifier nfs manual online. Surface mounted electrical boxes smb500 are available from notifier wiring note. Fdm 1 typical dual two wire style b initiating device circuit configuration. The box must have a minimum depth of 218.
All wiring must conform to applicable local codes ordinances and regulations. All wiring must conform to applicable local codes ordi. Mounting the fzm 1 mounts directly to 4 square electrical boxes see figure 2a. Address 56 then it will automatically assign itself to ad dresses 56. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. This module is intend ed for power limited wiring only.
Set the address on the module per job drawings. Surface mounted electrical boxes smb500 are avail able from notifier. Compatible notifier system control panels only list available from notifier. Surface mounted electrical boxes smb500 are available. This module is intended for power limited wiring only. Connecting a releasing device to the fcm 1 rel.
Variety of notifier fcm 1 wiring diagram. All wiring must conform to applicable local codes. Monitor modules supervise a circuit of dry contact input devices such as conventional heat detectors and pull stations or monitor and power a circuit of two wire smoke detectors. The box must have a minimum depth of 218. Wiring diagrams wiring diagrams the following wiring diagrams are included. For example if the fdm 1 is set to able from notifier.
Releasing applications c limited energy cable cannot be used to wire a. Compatible notifier system control panel list available from noti fier.