The power pack supports and automatically detects the line voltage input within the 100 277 vac range. Wiring diagram hubbell building automation inc.
Lighthawk 2 Wall Switch Occupancy Sensors
Hubbell uvpp wiring diagram. When required for increased load capacity or to control multiple voltages with one sensor uvpp or uvppm power packs can be connected as shown in the wiring digram below. The mps auxiliary packs require power form a uvpp series power pack to. Uvpp universal voltage power pack 100 277vac 5060hz add qti to end of catalog number for optional quick to install connector. The universal voltage power pack is a self contained transformer and relay an onoff switch controlled by a circuit designed for low voltage 24 vdc occupancy sensors. Nalexproduct managementlvsdinstallsarchivelvsd mluvppmpsadiagram layout1 1 author. 1do not attempt to power more than 4 devices be it sensors or slave packs from a single power pack.
Uvpp wiring diagram uvppm wiring diagram 72 00539. Automatic on occupancy configuration and operation. The power pack supports and automatically detects the line voltage input within the 100 277 vac range. This eliminates the need for voltage specific power packs. The universal voltage power pack is a self contained transformer and relay an onoff switch controlled by a circuit designed for low voltage 24 vdc occupancy sensors. The mps auxiliary pack is a self contained transformer and relay an onoff switch controlled by a circuit designed for low voltage 24vdc occupancy sensors.
Uvpphd manual onoff operation 4a. Neutral hot red 24vdc black common blue control red red black white uvppm power pack supplies 150ma hubbell building automation low voltage sensorsdevices requires 33ma each orange manual on override. This power pack is capable of switching 20a loads and features. This power pack is capable of switching 20a loads and features. Do not connect the red 24vdc wires together. 1 circuit4 sensors with uvppdwg.
An auxiliary pack is capable of switching a 15a mpsa or 20a mpshd loads and feature zero arc point switching minimizing relay contact wear from inrush loads. This eliminates the need for voltage specific power packs. Wiring diagrams powered by 24vdc supplied by uvpp or uvppm uvpp wiring diagram red black blue power pack contacts rated for 20 amps. The device is factory configured to operate in automatic on mode. Connect the unit to the circuit as shown in the wiring diagram fig. Cap off the red wire on all packs other than the first pack.
The maximum length of 18 22 awg wire between the control unit and associated sensors should not exceed 200ft. Uvpp power pack supplies 150ma hubbell building automation low voltage sensorsdevices requires 33ma each override switch optional note.