Removing rotary switch stop. Operation each fcm 1a or frm 1a uses one of 159 possible module addresses on a slc loop 99 on clip loops.
You Can Install The Wiring A Combination Ceiling Light Fan
Frm 1 wiring diagram. Variety of notifier fcm 1 wiring diagram. Set the address on the module per job drawings. Class b supervised wiring to the monitored device. The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. Fzm 1 zone interface monitor module. Module polarities are shown in alarm.
32f to 120f 0c to 49c dimensions. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools. 15 to 32 vdc. Fmm 1 connect modules to listed compatible notifier control panels only. The frm 1a provides two form c dry contacts that switch together. Surface mounted electrical boxes smb500 are available from notifier.
65 ma led on. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. Secure module to electrical box supplied by installer see figure 2a. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. Typical notification appliance circuit configuration nfpa style y. Install contact closure devices per manufacturers installation instructions.
Relay module wiring diagram. Page 5 wiring diagrams this page. 65 ma led on temperature range. 15 to 32 vdc maximum current draw. 4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. Typical fault tolerant notification appliance circuit configuration nfpa style z.
All wiring shown is supervised and power limited. Module mounting with barrier. Smaller size fits inside devices or junction boxes. Page 1 figure 1. Maximum slc current draw. The frm 1 mounts directly to 4 square electrical boxes see fig ure 2a.
Any number of ul listed contact closure devices may be used. Transmits the status of one zone of 2 wire detectors to the fire alarm control panel. Maximum slc current draw. All wiring shown is supervised and power limited. Connect modules to listed compatible notifier control panels only. 15 to 32 vdc.
It allows a compatible control panel to switch discrete contacts by code command. When using control modules in. Fmm 101 mini monitor module. Class a supervised wiring to the monitored device. A78 2611 11 a78 2610 08 specifications normal operating voltage. All wiring must conform to applicable local codes ordi nances and regulations.
Install module wiring in accordance with the job drawings and appropriate wiring diagrams. Removing general description rotary switch stop. The box must have a minimum depth of 21 8. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. The fcm 1a is configured for a single class b style y or class a style z notification appliance circuit.