The 2w its mounts through a ½ hole which may need to be made in the luminaire or could come pre punched by the luminaire supplier. By admin october 12 2018.
Used Bsl 310 Emergency Led Driver And Battery Backup For Sale
Bsl310 wiring diagram. Philips bodine bsl310 wiring diagram. The emergency driver must be charged for at least 24 hours before conducting a long term test. The yellow yelblk violet brown red and white converter connector wires are all class 2. Bsl310 emergency led driver. 2 wire input reduces wiring errors compatible with a variety of led strip manufacturers compatible with ac drivers and led loads rated for class 2 selectable output rohs compliant 140 225 118 145 dimensions 145 x 225 x 118 mounting center 140 led bsl310. Ul recognized factory installation indoor and damp output class 2 compliant bsl310 is field installable when used with the philips evokit led retrofit luminaire and installed by licensed.
Mount the supplied 2w its 2 wire illuminated test switch in a location that is visible and accessible by maintenance personnel. May be used with other drivers. Bsl310 091013 ni cd universal input class 2 output. Wiring diagrams 2 warning. Bsl310 102918 ni cd class 2 output. Emergency driver and ac driver must be fed from the same branch circuit typical schematics only.
Bsl310 is field installable when used with the philips evokit g2 led retrofit luminaire. 1534 x 225 x 118 369 mm x 58 mm x 30 mm. Wiring diagrams 4 note 1. Wiring diagram electrical wires cable schematic philips bsl310 emergency ballast by philips bodine 13522d6 bodine b50st emergency ballast wiring diagram library emergency led drivers w universal lighting technologies. High temperature maintenance free nickel cadmium battery 7 to 10 year life expectancy. Emergency driver for linear led strips class 2 output 10 watts output power.
An unswitched source of power is required. For short term testing of the emergency function the battery must be charged for at least one hour. See the wiring diagrams for details. Listed to ul924 and tested to csa 222 no. Option b contains the illuminated test switch wiring in its own conduit with the test switch and a wall plate included in a separate parts kit. Wire the test switch per wiring diagrams provided on these instructions.
2 wire illuminated test switch. Consult the factory for other wiring diagrams. Operates an led load of up to 10w at nominal battery voltage for a minimum of 90 minutes. Temperature rating ambient 0c to 55c 32f to 131f dimensions. The emergency driver must be fed from the same branch circuit as the ac driver. Option a the illuminated test switch is located in one conduit and product wiring in the other.
Ul listed for us and canada. Make sure the necessary branch circuit wiring is available. Bodine bsl310 emergency led driver 120277v up to 10 watt led emergency driver input voltage. To prevent high voltage from being present on yellow yellow. 141 for field or factory installation indoor and damp.