Extremely rugged simple design few parts. This principle is used to open the port of the valve by attaching a stem to the magnetic metal or plunger.
Valves 120v Coil
Sporlan mkc 1 wiring diagram. The solenoid valve operation is based on the theory of the electromagnet. 150 150 175 106 216 116 131 1valves with mounting holes use a 8 32 screw torqued not more than 15 in lb. This includes protection against. 4do not over tighten the enclosing tube locknut. If you would like to receive pricing andor paper copies of literature please contact your sales office or contact sporlan division by phone at 636 239 1111. The following is a selection of sporlan references available for download.
3coil housing must not be below horizontal. Can be used with most commercially available cfc hcfc and hfc. O mkc 1. 12050 60 j a k 30 y connector on end of leadwire b 14 female spade disconnect barrel insulated both wires na c 14 female spade disconnect fully insulated both wires p 14 female spade disconnect fully insulated only on one wire y 14 fork terminal barrel insulated n packard connector metri pak 15300027. Actual system piping must be done so as to protect the compressor at all times. 20 refrigerant distributors.
Solenoid valves with four wire dual voltage coils have a wiring diagram decal figure 3 on the. 2coil housing to be no more than 45 from the vertical. 30 solenoid valves. 2coil housing to be no more than 45 from the vertical. The 12 bx conduit connection or junction box on the coil may be rotated to any position by loosening the coil hexscrew. 3coil housing must not be below horizontal.
Connect power wires to terminals 1 and 2. All information is in portable document format pdf. Class f temperature rating coil types mkc 1 mkc 2 and omkc 2. Remove the protective clear film cover from the front of the temperature control. Tight closing through use of synthetic seating material. 40 catch all filter driers.
150 150 175 106 216 116 131 1valves with mounting holes use a 8 32 screw torqued not more than 15 in lb. Standard torque charts do not apply. Race catalogue 30 10 uk page 1 sporlan solenoid valves benefits molded coil for most sizes. Transformer requirements are 24 volts ac at 40va class ii. Connect the sporlan electric valve wires to terminals 5 6 7 and 8 matching the colors shown in the wiring diagram. Liquid line suction line hot gas etc.
10 thermostatic expansion valves. 958101 1390 000 coil screw 1 mkc 2 coil mkc 2 coil specify voltage frequency 1 183660 641 3 enclosing tube gasket 1 382150 13252. 50 isolation valves. E series may be brazed without disassembly. Bulletin bulletin 90 40 or other sporlan product literature the sporlan warranty is void. Standard torque charts do not apply.
Parker sporlan solenoid valves may be applied on a wide variety of air conditioning and refrigeration applications. Wiring check the electrical specifications of the coil to be sure they correspond to the available electrical service. 4do not over tighten the enclosing tube locknut.